1250°C DTA DSC Oit Differential Thermal Analysis Heat Analyzer
Product Summary
BAXIT Differential Thermal Analyzer BXT-DTA-1250 Instrument introduction Differential thermal analysis is a technique for measuring the temperature difference and temperature relationship between a substance and a reference substance under program-controlled temperature. The differential thermal ...
Product Custom Attributes
Basic Properties
Trading Properties
Product Description

Differential thermal analysis is a technique for measuring the temperature difference and temperature relationship between a substance and a reference substance under program-controlled temperature. The differential thermal analysis curve describes the temperature (△ T) relationship between a sample and a reference material as a function of temperature or time. In the DTA test, the change in sample temperature is caused by the endothermic or exothermic effects of phase transition or reaction. For example: phase transition, melting, crystal structure transformation, boiling, sublimation, evaporation, dehydrogenation reaction, fracture or decomposition reaction, oxidation or reduction reaction, lattice structure destruction, and other chemical reactions.
Instrument usePhase transition, melting, crystal structure transformation, boiling, sublimation, evaporation, dehydrogenation reaction, fracture or decomposition reaction, oxidation or reduction reaction, lattice structure destruction, and other chemical reactions.
Main features| Temperature range | Room temperature~1250℃ |
| Range of measurement | 0~±2000μV |
| Precision | ±0.01μV |
| Sensitivity | 0.01μV |
| Heating rate | 0.1~80℃/min |
| Temperature accuracy | 0.01℃ |
| Temperature resolution | 0.01℃ |
| Temperature fluctuation | ±0.01℃ |
| Temperature repeatability | ±0.1℃ |
| Sensor type | K-type and E-type can be switched freely (K-type standard, E-type optional) |
| Timing frequency | 16.6Hz |
| Experimental mode | FTC and STC can be set arbitrarily |
| Program temperature control | Flexible setting of 12 stage temperature control throughout the entire stage |
| Temperature control method | Heating,constant temperature ,cooling |
| Scan type | Heating, cooling, isothermal scanning |
| Number of scans | The number of cycle scans can be set up to 9999 times, and the data is automatically saved |
| Atmosphere control | Two atmospheres can be freely set, and the instrument automatically switches between them |
| Display mode | 24bit color 7-inch LCD touch screen display |
| Data interface | standard USB interface |
| Sampling rate | 1-10Hz programmable settings |
| Instrument calibration | The lower computer and upper computer both have multi-point temperature correction function |
| Parameter standard | Equipped with standard substances, users can self correct temperature and enthalpy |
| Power supply | AC 220V/50Hz or customized |
Contact Our Experts And Get A Free Consultation!
Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.